YOUR PRESSURE AND TEMPERATURE SWITCH SOURCE
MULTIFUNCTION
PRESSURE AND
TEMPERATURE SWITCHES
• SINGLE SETPOINT, FIXED DEADBAND
• SINGLE SETPOINT, ADJUSTABLE DEADBAND
• DUAL SETPOINT
BULLETIN SWGL-1
A Halliburton Company
Seitenansicht 0
1 2 3 4 5 6 ... 11 12

Inhaltsverzeichnis

Seite 1 - TEMPERATURE SWITCHES

13YOUR PRESSURE AND TEMPERATURE SWITCH SOURCEMULTIFUNCTIONPRESSURE ANDTEMPERATURE SWITCHES• SINGLE SETPOINT, FIXED DEADBAND• SINGLE SETPOINT, ADJUS

Seite 2 - G-SERIES

10DIMENSIONS – G-SERIES ENCLOSUREPressure Switch – psi RangesDifferential Pressure Switch –psi Differential RangesDifferential Pressure Switch –Inches

Seite 3 - L-SERIES

11DIMENSIONS – L-SERIES ENCLOSUREPressure Switch – psi RangesDifferential Pressure Switch –psi Differential RangesDifferential Pressure Switch –Inches

Seite 4 - G and L PRESSURE RANGES

12All specifications are subject to change without notice.All sales subject to standard terms and conditions.Copyright Dresser Instrument Division 9/9

Seite 5 - ● ●

2Dresser Control Instrument Opera-tion is a supplier of highly reliableAshcroft® switches and controls forindustrial and process applications.We stres

Seite 6 - G and L TEMPERATURE SWITCHES

3Hermetically Sealed SwitchWe recommend hermeticallysealed switch elements for im-proved reliability. The hermeticallysealed Ashcroft® switch provides

Seite 7 - 150°-260°F

4Pressure and DifferentialPressure SwitchesG- and L-Series pressure, differen-tial pressure and vacuum switchesuse two different actuators depend-ing

Seite 8 - SWITCH SELECTION INFORMATION

5 NOTES: 1. These items are wetted by process fluid. 2. Ambient operating temperature limits -20 to 150°F,all styles. Setpoint shift of ±1% of ra

Seite 9

6NOTES:1. Switches may generally be set between 15% and 100%of nominal range on increasing or decreasing temperature. Consult factory for applica

Seite 10 - 3.7 lb. 1.7 kg 4.5 lb. 2.0 kg

7 SWITCH CONTROLS FOR FOR GTD/LTD & GTS/LTS CONTROLSCode Single DualSwitch elements(LS) (LD)UL/CSA listedK(2)KK Narrow deadband 15A, 1

Seite 11

8PRESSURE, TEMPERATURE ANDDIFFERENTIAL PRESSURE SWITCHSELECTIONBefore making your selection, please considerthe following:1. ActuatorThe actuator resp

Seite 12

9Accuracy – (See repeatability). Accuracy nor-mally refers to conformity of an indicated valueto an accepted standard value. There is no in-dication i